• DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids
  • DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids
  • DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids
DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids

DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids

Produktdetails:

Herkunftsort: CHINA
Markenname: Dupont
Zertifizierung: CE
Modellnummer: SFP-2880
Dokument: UF-IntegraTec-P-Series-PVDF...en.pdf

Zahlung und Versand AGB:

Min Bestellmenge: 1 PC
Preis: verhandelbar
Verpackung Informationen: Standard -Exportpackung
Lieferzeit: 5- 8 Arbeitstage
Zahlungsbedingungen: , T/t
Versorgungsmaterial-Fähigkeit: 60000 Einheiten pro Monat
Bestpreis Kontakt

Detailinformationen

Modulflussbereich von SFP-2880: 40 ̊90 LMH (24 ̊53 gfd) bei 25°C 2880-Modul-Durchflussrate von SFP-2880: 2,0–6,9 m³/h (8,8–30,4 gpm)
2880-Modultemperaturgrenzen von SFP-2880: 1°C bis 40°C Modul Max Operating TMP von SFP-2880: 2,1 bar (30,5 psi)
Chemische Toleranz von SFP-2880: Stand bis zu 2.000 mg/l Naocl Optimiertes Design von SFP-2880: 77m2
Modulbreiter Anwendungsbereich von SFP-2880: Geeignet für die Aufbereitung von Oberflächenwasser, Meerwasser, kommunaler Trinkwasserproduktion Membrantyp SFP-2880: Industrielle Ultrafiltrationsmembrankomponenten

Produkt-Beschreibung

DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids
Product Overview

The DuPont™ SFP-2880 is an 8-inch, high-flow ultrafiltration membrane module engineered for superior performance in large-scale water treatment systems. Featuring a robust, hydrophilic PVDF hollow fiber design with a precise 0.03-micron pore rating, it ensures exceptional removal of bacteria, viruses, and colloids, providing reliable protection for downstream processes like reverse osmosis. Its outside-in filtration configuration allows it to handle challenging feed water with high suspended solids, reducing pretreatment needs. With a large 77 m² membrane area, it delivers an economical solution for systems over 50 m³/hr, offering excellent durability, lower operating costs, and compact system design for municipal and industrial applications such as surface water treatment, wastewater reuse, and seawater pretreatment.

Key Features
  • Advanced Filtration Performance: Removes bacteria, viruses, and colloids with high efficiency; achieves filtrate turbidity below 0.1 NTU and SDI under 2.5; ideal protection for reverse osmosis systems
  • Engineered Durability: Chemical-resistant PVDF membrane withstands extreme pH conditions; U-PVC housing eliminates need for pressure vessels; operating temperature range supports global deployments
  • High-Efficiency Design: Industry-leading membrane area enables high flow rates; outside-in flow handles high solids loading; reduced backwash frequency lowers water consumption
  • Operational Reliability: Consistent performance in municipal and industrial settings; minimal maintenance requirements; compatible with automated control systems
Technical Specifications
Attribute Value
UF Module Flux Range 40–90 LMH (24–53 gfd) at 25°C
Flow Rate per Module 2.0–6.9 m³/hr (8.8–30.4 gpm)
UF Module Temperature Limits 1–40°C (34–104°F)
UF Module Max Operating TMP 2.1 bar (30.5 psi)
Chemical Tolerance Withstands up to 2,000 mg/L NaOCl
Membrane Area 77m²
Membrane Type Industrial Grade Ultrafiltration Membrane Components
Product Specifications
Model Type Part # Membrane Area (m²/ft²) Volume (Liters/Gallons) Weight (Kg/lbs)
SFP-2880 Pretreatment 280934 77 / 829 39 / 10.3 61 / 135 (empty), 100 / 220 (water filled)
SFD-2880 NSF/ANSI 61 Drinking water 324169 77 / 829 39 / 10.3 61 / 135 (empty), 100 / 220 (water filled)
DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids 0
Operating Parameters
Parameter SI Units US Units
Filtrate Flux @ 25ºC 40-120 l/m²/hr 24-70 gfd
Flow range 3.1-9.3 m³/hr 13.6 - 40.9 gpm
Temperature 1-40ºC 34-104ºF
Max. inlet module pressure (@ 20ºC) 6.25 bar 93.75 psi
Max. operating TMP 2.1 bar 30 psi
Max operating air scour flow 12 nm³/hr 7.1 scfm
Max backwash pressure 2.5 bar 36 psi
Operating pH 2-11
Important: If operating limits and guidelines given in this bulletin are not strictly followed, the limited warranty will be null and void. To prevent biological growth during system shutdowns, it is recommended that preservative solution be injected into the membrane modules.
Module Installation
DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids 1 DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids 2

For application cases, please visit: www.fgwater.com/Industries/

Möchten Sie mehr über dieses Produkt erfahren?
Ich bin daran interessiert DuPont™ SFP-2880 UF Membrane - Superior Removal of Bacteria, Viruses & Colloids Könnten Sie mir weitere Details wie Typ, Größe, Menge, Material usw. senden?
Vielen Dank!
Auf deine Antwort wartend.